*All mCookie function pins are connected to the base board of the Hub, including digital, analog, serial port and IIC interface.
 
*All mCookie function pins are connected to the base board of the Hub, including digital, analog, serial port and IIC interface.
*Hub's interface rules: '''GND, VCC, signal 1 and signal 2'''.
+
*Hub's interface pinout per header: '''GND, VCC, signal 1 and signal 2'''.
  
 
*Two IIC interfaces.
 
*Two IIC interfaces.
  
*Pin Description:
+
===Pin Description===
 
Sensor interface rules: '''GND, VCC, signal 1 and signal 2 ''' or '''GND, VCC, signal 1 and NC(empty)'''.  
 
Sensor interface rules: '''GND, VCC, signal 1 and signal 2 ''' or '''GND, VCC, signal 1 and NC(empty)'''.  
 
Hub interface rules: '''GND, VCC, signal 1 and signal 2 '''.  
 
Hub interface rules: '''GND, VCC, signal 1 and signal 2 '''.  

Revision as of 21:21, 29 March 2017

Language: English  • 中文
MCookie-Hub-rect.jpg

mCookie-Hub is designed for ease of the connection between Microduino Sensor Series and the core modules on the UPIN27 base board as well as further extended experiment.

The sensor / trinket connector are 4 pin, 1.25mm pitch JST connectors.






Features

  • Integrate twelve sensor interfaces;
  • Small size with sensor interface integrated on the Upin 27 base board;
  • All function pins are extended;
  • Prevent reverse sensor connection
  • Uses 4 pin, 1.25mm pitch JST headers

Specification

  • All mCookie function pins are connected to the base board of the Hub, including digital, analog, serial port and IIC interface.
  • Hub's interface pinout per header: GND, VCC, signal 1 and signal 2.
  • Two IIC interfaces.

Pin Description

Sensor interface rules: GND, VCC, signal 1 and signal 2 or GND, VCC, signal 1 and NC(empty). Hub interface rules: GND, VCC, signal 1 and signal 2 .

  • Such as:
    • Photosensitive sensor interface rules: GND, VCC, signal 1 and NC(empty). Since it is analog sensor, you can detect(A0-A7) by analog port. Seen from the picture, the hub can be connected to the location of 10, 11 and 12, and the corresponding pins are A6, A2 and A0.
    • Since the temperature and humidity sensor uses IIC interface, we can connect it to "1" or "2".